Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.502)
www.elmomc.com
74
Feature Details Connector Location
High-speed
inputs 5 & 6 -
minimum pulse
width, in high-
speed mode
T < 5 µsec
Notes:
• Home mode is high-speed mode and can
be used for fast capture and precise
homing.
• High speed input has a digital filter set to
same value as digital filter (EF) of main
encoder.
• Highest speed is achieved when turning
on optocouplers.
Comentarios a estos manuales