IP and IB[N] can be used to detect a logically active switch of all defined
functions, excluding function 2 (“No function is attached”).
Attributes: Type: Parameter, Bit-field
Assignment: Yes
Source: Program, RS-232, CANopen
Restrictions: None
Default value: IL[1]=0
IL[2…10]=7 (RS), Non-volatile
Range: According to previous description
Index range: [1…10]
Unit modes: All
Activation: Immediate
Reference chapter in the SimplIQ for Steppers Application Note:
Chapter 12, “The Position Reference Generator”
See also:
UM
, RM, JV, PX, BG, IP, IB[N], HM[N], HY[N]
SimplIQ for Steppers Command Reference Manual Alphabetical Listing