Error
Code
Error String / Description
Example / Remedy
164 EC command (not an error). For internal use.
165 An attempt to access serial flash while busy.
Failure on reading serial flash memory,
possibly due to a hardware problem.
Contact Technical Support.
166 Out of modulo range. XM[1]=-1000, XM[2]=1000 and
PA=2000 is an error because the
modulo range is [-1000…999].
Therefore, the position of
PA=2000 can never be reached.
167 Infinite loop in for loop - zero step k=1:0:10; causes this error.
168 Speed too large to start motor.
MO=1 or motor started with Enable switch
while motor was rotating too quickly.
Starting a running motor may fail
if the back EMF is too high and
induces an immediate excessive
motor current.
Table 3-10: Processing Error Codes
Attributes: Type: Status report, Integer
Source: RS-232, CANopen
Restrictions: None
Unit modes: All
SimplIQ: Modified
See also:
MF
, SR
SimplIQ for Steppers Command Reference Manual Alphabetical Listing