Setting EM[1] to 1 or 2 will fail if EM[2] is less than or equal to EM[5],
or if EM[4] is less than or equal to EM[7].
Changing the last segment with EM[7] may cause a reference jump.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: Advanced model only
Default values: EM[1]=0, EM[2]=2, EM[3]=0, EM[4]=1000,
EM[5]=1, EM[6]=1, EM[7]=0, EM[8]=0
(RS), Non-volatile
Range: EM[1]: [0…2]
EM[2]: [2…1024]
EM[3]: Position counter range
EM[4]: [1…32,000]
EM[5]: [1…1023]
EM[6]: [1…1024]
EM[7]: 1…32,000]
Index range: Write: [1…7]
Read: [1…8]
Unit modes: UM=3, 4, 5
Activation: See previous Notes
SimplIQ: Similar
See also:
RM
, FR[N]
Application note:
The Position External Reference Generator
SimplIQ for Steppers Command Reference Manual Alphabetical Listing