Elmomc SimplIQ Digital Servo Drives-Bell Command Referenc Manual de usuario Pagina 195

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 315
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 194
Notes:
Changing YA[4] resets the position sensor thus resetting the homing position.
Changing YA[5] does not change PY. It only defines in which direction future
encoder pulses will be counted.
SimplIQ difference: Encoder output is only available for quadrature Main
encoder.
SimplIQ difference: OC[N] runs correctly regardless of the YA[4] state.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: MO=0
Default values: YA[1]…YA[3]=0 (RS), Non-volatile
YA[4]=2, YA[5]=0 (RS), Non-volatile
Range: As in previous table
Index range: [1…5]
Unit modes: All
Activation: Immediate
SimplIQ: Modified
See also: OC[N]
SimplIQ for Steppers Command Reference Manual Alphabetical Listing