Elmomc SimplIQ Digital Servo Drives-Bell Command Referenc Manual de usuario Pagina 60

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 315
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 59
Error
Code
Error String / Description
Example / Remedy
119 Bad Analog sensor Filter When the filter KV, set for analog
feedback, is beyond its legal
range.
120 Bad number of blocks for Analog sensor
filter
When the analog sensor filter
contains a wrong number of
blocks.
121 Analog sensor is not ready When the initiation procedure of
the Analog sensor was not
completed, and the motor is being
enabled.
123 Motion control processor does not respond.
Possibly, firmware has not been well loaded.
127 Modulo range must be positive.
XM[2] is less or equal to XM[1] or
YM[2] is less or equal to YM[1].
128 Bad variable index in database - internal
compiler error.
Index of the variable in the database is not
correct.
An internal compiler error occurs
due to a corrupted database. In
such a case, email Technical
Support for assistance. Attach the
Composer date and version (found
in the Help menu) and the program
you attempted to compile.
129 Variable is not an array.
Cannot access a scalar variable defined
according to its index in square brackets as
an array in the user program.
Assume that a scalar variable has
been defined in the user program
as a:
long a;
The expression a[0]=1; is wrong
because a is defined as scalar and
not an array.
130 Variable name does not exist.
For
SimplIQ for Steppers internal use.
131 Cannot record local variables.
For SimplIQ drive internal use.
132 Variable is not an array.
For
SimplIQ drive internal use.
SimplIQ for Steppers Command Reference Manual Alphabetical Listing
MAN-STECR (Ver. 1.1)