Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: MO=0
MO=1 and SV cannot be used before XM[2]
and XM[1] are activated (see “Activation”
below)
Default values: XM[1]=-5x10
8
, XM[2]=5x10
8
(RS), Non-volatile
Range: Position range
Unit modes: All
Activation: XM[2] > XM[1] and XM[2] - XM[1] is an even
number
SimplIQ: Modified – range changed
See also:
YM[N]
, PX
SimplIQ for Steppers Command Reference Manual Alphabetical Listing
MAN-STECR (Ver. 1.1)