VC[N]- Voltage Command
Purpose:
Defines the voltage output of the Q and the D controllers, over-riding the control
functions.
VC[1] sets VQ
VC[2] sets VD
The units for VQ and VD are fractions of the available bus voltage.
Attributes: Type: Parameter, float
Source: Program, RS-232, CANopen
Restrictions: MO=1
Default value: 0 -volatile
Range: [0…0.95]
Unit mode 0
Activation: Immediate
SimplIQ: New command
Note:
• VQ and VD do not compensate on line voltage changes.
See also:
UM
Application notes:
The current controller
Current output transformation