Attributes: Type: Parameter, Real
Source: Program, RS-232, CANopen
Restrictions: None
Index range: [1,11]
Unit modes: All
Activation: Immediate
SimplIQ: No
Under most circumstances, this command is used only by the tuning
environment.
See also:
PF[18],PF[19]: - MF
Application notes:
PF[1]: Motor inductance corrections
PF[2]: BEMF corrections
PF[3,4,5]: Cogging correction
PF[9],PF[12]: Current loop implementation
PF[16],PF[17]: Torque and position reference generation for open loop stepper
PF[29]: Closed loop stepper control