Bassoon Installation Guide Technical Specifications
MAN-BASIG (Ver. 1.502)
www.elmomc.com
64
4.8.2. Digital Output Interface
Feature Details Connector Location
Type of output
• Optically isolated
• Open collector and open emitter
Maximum supply
output (Vcc)
30 V
Maximum output
current
Io (max) (Vout =
Low)
Iout (max) ≤ 10 mA
VOL @ maximum
output voltage (low
level)
Vout (on) ≤ 0.3 V + 0.02 * Iout (10 mA)
RL External resistor RL must be selected to
limit output current to no more than 10
mA.
Executable time If output is set to one of the built-in
functions — Home flag, Brake or AOK —
execution is immediate upon detection:
0 < T < 4 x TS
If output is set to General output and is
executed from a program, the typical
time is approximately 0.5 msec.
Rout = 20Ω
33v
OUTput Ret(i)
OUTput (i)
HAR0061A
Figure 33: Digital Output Schematic