3.5.7. I/O Cables
The following table lists the I/O cables that you should connect according to your specific
requirements:
I/O Description Total Port
Digital input 6 J5
Digital output 2 J6
Analog input 1 J7
3.5.7.1. Digital Input (Port J5)
Notes for connecting the digital input cable:
• Use 24 or 26 AWG twisted pair shielded cable.
• Connect the cable shield to the ground near the signal source (controller) according to the
manufacturer’s recommendations.
Pin Signal Function Pin Positions
1 IN1 Programmable input 1
(general purpose, RLS, FLS, INH)
2 IN2 Programmable input 2
(general purpose, RLS, FLS, INH)
3 IN3 Programmable input 3
(general purpose, RLS, FLS, INH)
4 IN4 Programmable input 4
(general purpose, RLS, FLS, INH)
5 IN5 Programmable input 5
(event capture, Main Home,
general purpose, RLS, FLS, INH)
6 IN6 Programmable input 6
(event capture, Auxiliary Home,
general purpose, RLS, FLS, INH)
7 INRET Programmable input return
8 INRET Programmable input return
Table 12: Digital Input Cable Pin Assignments