3.5.3. Connecting the Auxiliary Power Cable (J4)
Connect the auxiliary power supply to the J4 port on the front of the Bassoon, using a
2-pin Molex plug. Remember, you are working with DC power; be sure to exercise caution. The
required voltage is 24 VDC.
Notes for 24 VDC auxiliary power supply connections:
• Use a 24 or 26 AWG twisted pair shielded cable.
• The 24 VDC auxiliary power supply must meet all safety requirements and must be
separated from hazardous live voltages using reinforced or double insulation in accordance
with approved safety standards.
• For safety reasons, connect the return (common) of the 24 VDC source to the closest
ground.
• Connect the cable shield to the closest ground near the 24 VDC source.
• Before applying power, first verify the polarity of the connection.
Pin Signal Function Pin Positions
1 +24VDC +24 VDC auxiliary power supply
2 RET24VDC Return (common) of the 24 VDC
auxiliary power supply
Table 3: Auxiliary Power Cable Plug
Figure 9: Auxiliary Power Supply (J4) Connection Diagram