Elmomc SimplIQ Command Reference Manual de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 188
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
DC - Deceleration
Purpose:
Defines the maximum deceleration in counts/seconds
2
. This parameter is used in
profiled speed control mode (UM=2, PM=1) and in position point-to-point (PA, PR) and
jogging (JV) motions (UM=3, UM=4 and UM=5). The DC parameter does not affect the
present motion. It is used to plan the next motion, initiated by a BG command.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: None
Default values: 20,000,000 (RS), Non-volatile
Range: Deceleration range
Unit modes: UM=2, 3, 4, 5
Activation: BG for RM=0, MO=1 for RM=1
See also:
AC, SP, PA, PR, BG
Reference chapter the SimplIQ Software Manual:
Chapter 12, ”The Position Reference Generator”
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-27
Vista de pagina 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 187 188

Comentarios a estos manuales

Sin comentarios