Elmomc SimplIQ Command Reference Manual de usuario Pagina 179

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 188
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 178
Notes:
Changing YA[4] resets the position sensor thus resetting the homing position.
Changing YA[5] does not change PY. It only defines in which direction future
encoder pulses will be counted.
Changing the auxiliary sensor configuration while Output Compare is active may
cause unpredictable drive behavior. No warning or error is given.
For some Output Compare signal sources, the auxiliary sensor must be configured
as output. Setting auxiliary sensor as input is illegal.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: MO=0
Default values: YA[1]…YA[3]=0 (RS), Non-volatile
YA[4]=2, YA[5]=0 (RS), Non-volatile
Range: As in previous table
Index range: [1…5]
Unit modes: All
Activation: Immediate
See also: OC
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-166
Vista de pagina 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 187 188

Comentarios a estos manuales

Sin comentarios