Ocarina Evaluation Board User Guide Evaluation Board Connectors and Cables
MAN-EVLBRD-OCA (Ver. 2.2)
2-8
2.5.2 Connecting Main Power
Connect the main power supply cable to the VP+ and PR terminals of the main power connector.
Notes for connecting the DC power supply:
The source of the 0 ~ 95 VDC Main Power Supply must be isolated.
For best immunity, it is highly recommended to use twisted and shielded cables for the
DC power supply cable. A 3-wire shielded cable should be used. The gauge is determined
by the actual current consumption of the motor.
Connect the cable shield to the closest ground connection near the power supply.
Connect the PE to the closest ground connection near the power supply.
Connect the PR to the closest ground connection near the power supply.
Figure 2-4: Main Power Supply Connection Diagram
2.6 The Auxiliary Supply Connector
Pin Function Pin Positions
VL Auxiliary Supply Input
PR Power Input Return
2-Pole Header
Connector
2-Pole Plug
Table 2-2: Auxiliary Supply Connector