Elmomc CANopen DSP 402 Implementation Guide Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Object 0x6097: Acceleration factor
This object converts the acceleration (in acceleration units/second
2
) into the internal
format (in increments/second
2
).
Object description:
Index 6097h
Name Acceleration factor
Object code ARRAY
Data type UNSIGNED32
Category Optional
Entry description:
Sub-index 0
Description Number of entries
Entry category Mandatory
Access Read only
PDO mapping No
Value range 2
Default value 2
Sub-index 1
Description Numerator
Entry category Mandatory
Access Read/write
PDO mapping No
Value range UNSIGNED32
Default value 1
Sub-index 2
Description Divisor
Entry category Mandatory
Access Read/write
PDO mapping No
Value range UNSIGNED32
Default value 1
CANopen DSP 402 Implementation Guide
MAN-CAN402IG (Ver. 1.2)
51
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 115 116