Elmomc CANopen DSP 402 Implementation Guide Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
CANopen DSP 402 Implementation Guide
MAN-CAN402IG (Ver. 1.2)
35
Object 0x605E: Fault reaction option code
Object description:
Index 605Eh
Name Fault reaction option code
Object code VAR
Data type INTEGER16
Category Optional
Entry description:
Access Read/write
PDO mapping No
Value range INTEGER16
Default value 0
Data description:
Value Description
-32,768…-1 Manufacturer specific
0 Disable drive function
1…4 Not supported
1…32,767 Reserved
Notes:
An attempt to set an unsupported value causes the transmission of abort
code 0609 0030: Value exceeded.
All drive faults are considered fatal. When a fatal fault occurs, the drive is
no longer able to control the motor, requiring that the drive be switched-off
immediately.
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 115 116

Comentarios a estos manuales

Sin comentarios