Cymbal Installation Guide Installation
MAN-CYMIG (Ver. 1.3)
20
Figure5:IsolatedDCPowerSupply
Inthiscasetheisolationisachievedbytheisolationtransformer.
Itishighlyrecommended toconnectthenetworkPEtotheReturn(negative terminal) ofthe
PowerSupply.
Figure6:IsolatedPowerSupply
Inthiscasetheisolationisachievedbyusingabattery.
ItishighlyrecommendedtoconnectthePEtotheReturn(negativeterminal)ofthePower
Supply.
3.5.1.2.b OperationwithaNon‐IsolatedDCpowerSupply:
ThePE(ProtectiveGroundoftheACnetwork)mustnotbeconnectedtotheNegativePower
Input(theVN‐terminal) oftheCymbal.