SimplIQ Software Manual Program Development and Execution
MAN-SIMSW (Ver. 1.4)
6-32
Run to the nearest end of line.
Compare the current base pointer with the saved base pointer.
If the current base pointer is less than the saved base pointer, the step is out: jump to the
end of the loop. Otherwise, go to the start of the loop.
End of loop.
When the nearest end of line is reached and the current base pointer is less than the saved
base pointer, the VAC machine enters a halt state. Otherwise, it simply runs and does not
enter the halt state.
6.7.10 Getting Stack Entries
The DB##GS command returns relevant entries of the stack.
Syntax:
DB##GS[N]=N1,N2
where:
N is a handle of a specified VAC machine whose stack is queried.
N1 is an index of the first stack entry.
N2 is an index of the last stack entry (not inclusive).
The command returns a string containing hexadecimal binary data with a sequence of stack
entries from N1 to N2. If a single stack entry is of interest, then N2 = N1+1.
The command, which is very useful during debugging, returns a string in the hexadecimal
binary format. Every stack entry contains the following fields:
Name
Meaning
Data Type
Size
in Bytes
1 value Stack entry value Float or long,
depending on type
4
2 type Type of stack entry: 0 for long, 1 for float Signed short 2
3 unused Offset for alignment Signed short 2
6.7.11 Setting the Stack
The DB##ST command sets a stack entry, which must be a local variable or an input/output
argument of the function.
Syntax:
DB##ST[N]=N1,N2
where:
N is a handle of a specified VAC machine (2 bytes, signed short).
N1 is a stack pointer (2 bytes, signed short).
N2 is a new variable value (4 bytes, long or float).
In order to change a value of a local variable, DB##SS sets a new value to the relevant stack
entry for a specified VAC machine. The type of stack entry is set according to the type of
value that is sent.