Elmomc Multi-Axis Motion Controller-Maestro Manual de usuario Pagina 209

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 313
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 208
Maestro Software Manual Ethernet/IP Communication
MAN-MASSW (Ver. Q)
11-7
Figure 11-10: Remove Adapter Tag
11.5 UCMM (Unconnected) Messaging
11.5.1 Server (Maestro) UCMM (Unconnected) Messaging
Maestro client functionality allows sending unconnected messages to the scanner
(Rockwell) device. In order to use it, the Ethernet/IP device resource and appropriate
tags must be created. Tags have to be created with the same names defined on the
scanner (Rockwell) device side.
11.5.1.1 User interface to create communication objects
To create communication objects, follow the steps in the ELMO Studio user interface:
1. In the Workspace window, select the EIP View page.
2. Use the context menu to add a device as shown Fig 11-6. The following dialog box
will open:
Figure 11-11: Defining the EIP Device
3. In the Name field, enter the device name. This name is a logic name specified in
the Maestro Workspace only.
4. In the Network Path field, enter the full Ethernet path of the appropriate
Rockwell device Ethernet module.